arrow_back Back
Incident No.11
Date14 Mar 2026
Incident TypeNear Miss
StatusClosed
FacilityKemari Terminal
AreaTank yard
Responsible DeptStationary
Assigned To
Target Date
Created by System Administrator on 09 Jul 2026 05:00
Description

At tank # 56, during fit up activity of 3rd shell course, the tack weld of the U-fit up accessories broke as a result of hammering and fell down in the barricaded area. No injury or damage occurred.

Recommendations

Enhance the quality of welding joints to ensure they can sustain vibration and mechanical stress without failure.