Safety Observations — All Years

1473
Total
2
Open
1471
Closed
Open: 2, Closed: 1471.
Open Closed
Unsafe Act: 609, Unsafe Condition: 864, Near Miss: 0, Positive: 0.
Unsafe Act Unsafe Cond.
Procedure: 424. PPE: 232. Work at Height: 204. Electrical: 118. Housekeeping: 113. Lack of Supervision: 95. Equipment: 70. Slip/Trip/Fall: 53. Environment: 42. Line of Fire: 42. Vehicle: 36. Falling Object: 35. PTW: 6. Health: 2. Ergonomics: 1.
PRL: 121, Contractor: 1352.
PRL Contractor

By Department

Construction: 843. Stationary: 442. Civil: 129. Electrical: 17. Logistic: 15. Operation: 9. OM KT: 7. A&S: 4. Rotary: 3. Tank Farm: 2.

By Contractor

DEL: 442. ATL: 366. IIW: 219. AJC: 188. UE: 29. RE: 24. AKS: 19. WMS: 11. Afzal: 9. OMC: 9.

Monthly Trend

Jul 2025: 60. Aug 2025: 309. Sep 2025: 103. Oct 2025: 86. Nov 2025: 77. Dec 2025: 71. Jan 2026: 128. Feb 2026: 94. Mar 2026: 124. Apr 2026: 213. May 2026: 71. Jun 2026: 128. Jul 2026: 9.
Observations List 1473 records
No Date Type Department Description Assigned To Status Closed Date Actions
293 25 Aug 2025 Unsafe Condition Stationary At Desalter area, gas cylinder trolley was found on walkway, … team Closed 26 Aug 2025
292 25 Aug 2025 Unsafe Condition Civil At different locations of pump gallery, leftover scaffolding … team Closed 26 Aug 2025
291 24 Aug 2025 Unsafe Act Stationary Since the start of the shutdown, the HSE lead for the night … team Closed 23 Aug 2025
290 24 Aug 2025 Unsafe Condition Stationary At 101-E, 102-C, exchanger head cover was placed without are … Closed 25 Aug 2025
289 24 Aug 2025 Unsafe Act Stationary In the furnace area, a scaffolder was observed lifting three … Closed 25 Aug 2025
288 24 Aug 2025 Unsafe Condition Stationary At boiler & 3, during work at height, the area was not b … Closed 25 Aug 2025
287 24 Aug 2025 Unsafe Condition Stationary At 105-C7, material placed on platform posing a tripping haz … Closed 26 Aug 2025
286 24 Aug 2025 Unsafe Act Stationary At 105-C2, UE workers were observed performing job without w … Closed 25 Aug 2025
285 24 Aug 2025 Unsafe Act Stationary At 2201-F, during work at height, DEL team was not using the … team Closed 09 Jul 2026
284 23 Aug 2025 Unsafe Condition Stationary A hot job was carried out in the Utility and Pump Gallery, b … Closed 24 Aug 2025
283 23 Aug 2025 Unsafe Condition Stationary At multiple locations (below area of AFC, utility, heat exch … Closed 24 Aug 2025
282 23 Aug 2025 Unsafe Act Stationary At 301-F while working at height, M/s DEL worker was using s … Closed 24 Aug 2025
281 23 Aug 2025 Unsafe Act Stationary At 304-C, while working at height M/s DEL TE was found scaff … Closed 24 Aug 2025
280 23 Aug 2025 Unsafe Act Stationary At the Utility and Pump Gallery, sparks were observed coming … Closed 24 Aug 2025
279 22 Aug 2025 Unsafe Act Stationary At multiple locations (furnace area, road 5, heat exchanger … Closed 23 Aug 2025
278 22 Aug 2025 Unsafe Act Stationary At road 10 near fire camp,M/s DEL’s truck was observed carry … Closed 23 Aug 2025
277 22 Aug 2025 Unsafe Condition Stationary At 123C And 124C leftover material was found. Informed to M/ … Closed 23 Aug 2025
276 22 Aug 2025 Unsafe Condition Stationary At plant center, during crane operation M/s DEL team standin … Closed 23 Aug 2025
275 22 Aug 2025 Unsafe Condition Stationary At the Utility and Pump Gallery, sparks were observed coming … Closed 23 Aug 2025
274 22 Aug 2025 Unsafe Act Stationary At 304-C, while working at height M/s DEL TE was found scaff … Closed 23 Aug 2025