Date FY · Q Facility Area Description Department Target Status Assigned Actions
08 Jan 2026 2025-26 · Q2 Korangi Refinery Tank Farm
Road # 14
Sludge in rain drum and dry bushes was observed along road No. 14, nee … Civil Closed
08 Jan 2026 2025-26 · Q2 Korangi Refinery Tank Farm
WWTP
Railing of new constructed pit for effluent line near WWTP was found m … Construction Closed
08 Jan 2026 2025-26 · Q2 Korangi Refinery Tank Farm
API separator
Railing of API separator was found damaged, need to be repaired. Stationary Closed
08 Jan 2026 2025-26 · Q2 Korangi Refinery Tank Farm
API separator
Hay basket, dry leaves and other left over materials need to be remove … Stationary Closed
08 Jan 2026 2025-26 · Q2 Korangi Refinery Tank Farm
Crude pump office
Near crude pump office, decanting board of lube oil drums was pitted a … Stationary Closed
08 Jan 2026 2025-26 · Q2 Korangi Refinery Tank Farm
1101-CA
Steam drain line's funnel of 1101-CA was found damaged and not properl … Stationary Closed
08 Jan 2026 2025-26 · Q2 Korangi Refinery Tank Farm
1101-JB
Insulation was missing on 1101-JB discharge line. Civil Closed
08 Jan 2026 2025-26 · Q2 Korangi Refinery Tank Farm
1101-JB
Grass was grown on pneumatic valve of 1101-JB, need to be remo Civil Closed
08 Jan 2026 2025-26 · Q2 Korangi Refinery Tank Farm
1101-JB/JO
Nuts of strainer flange of 1101-JB/JO pump was missing. Stationary Closed
08 Jan 2026 2025-26 · Q2 Korangi Refinery Tank Farm
Tank # 4
Sand bags and left over material were found near crude pump, condenser … Civil Closed
24 Oct 2025 2025-26 · Q1 Korangi Refinery Process & Utilities
Plant Area
At LPG to MCOs iso-valves pit , safety sign board to be renewed. Operation Closed
24 Oct 2025 2025-26 · Q1 Korangi Refinery Process & Utilities
Plant Area
Near 2404-J drain channel to be cleaned. Civil Closed
24 Oct 2025 2025-26 · Q1 Korangi Refinery Process & Utilities
Plant Area
Old softening unit drain lines was found rusty need to be replaced. Stationary Closed
24 Oct 2025 2025-26 · Q1 Korangi Refinery Process & Utilities
Plant Area
Near LPG to MCOs iso-valves , lines supports were found in deteriorat … Civil Closed
24 Oct 2025 2025-26 · Q1 Korangi Refinery Process & Utilities
Plant Area
Near 2401-L , Concrete pipe rack and supports were found in deteriorat … Civil Closed
24 Oct 2025 2025-26 · Q1 Korangi Refinery Process & Utilities
Plant Area
Instrument Cables conduiting to be carried out around Cooling tower ba … Instrument Closed
24 Oct 2025 2025-26 · Q1 Korangi Refinery Process & Utilities
Plant Area
Electrical Cables conduiting to be carried out around Cooling tower ba … Electrical Closed
24 Oct 2025 2025-26 · Q1 Korangi Refinery Process & Utilities
Plant Area
Tagging of CW side stream pump ( 2302-J) was found missing. Civil Closed
24 Oct 2025 2025-26 · Q1 Korangi Refinery Process & Utilities
Plant Area
At Cooling water supply flowmeter, metallic plate handles to be fixed … Stationary Closed
24 Oct 2025 2025-26 · Q1 Korangi Refinery Process & Utilities
Plant Area
Plant area dust bins was damaged, need to be replaced. A&S Closed
24 Oct 2025 2025-26 · Q1 Korangi Refinery Process & Utilities
Plant Area
Around 201-C4 area housekeeping is required. Operation Closed
24 Oct 2025 2025-26 · Q1 Korangi Refinery Process & Utilities
Plant Area
MP steam tie-in point near 101-E first platform above 125-J , clamped … Stationary Closed
24 Oct 2025 2025-26 · Q1 Korangi Refinery Process & Utilities
Plant Area
Near 113-J concrete slab was found damaged. Civil Closed
24 Oct 2025 2025-26 · Q1 Korangi Refinery Process & Utilities
Plant Area
Wild bushes need to be removed from TK-44 yard and around utility tran … Civil Closed
24 Oct 2025 2025-26 · Q1 Korangi Refinery Process & Utilities
Plant Area
At Tk-44 yard, poor housekeeping was observed. Operation Closed