Safety Observations — All Years

1483
Total
9
Open
1474
Closed
Open: 9, Closed: 1474.
Open Closed
Unsafe Act: 609, Unsafe Condition: 874, Near Miss: 0, Positive: 0.
Unsafe Act Unsafe Cond.
PPE: 271. Work at Height: 208. Housekeeping: 149. Lack of Supervision: 144. Slip/Trip/Fall: 124. Electrical: 121. Equipment: 91. Procedure: 88. Line of Fire: 63. Falling Object: 52. Vehicle: 52. Environment: 44. Fire: 21. Health: 17. Emergency Response: 17. PTW: 12. SIMOP: 5. Pressure: 3. Ergonomics: 1.
PRL: 112, Contractor: 1371.
PRL Contractor

By Department

Construction: 835. Stationary: 475. Civil: 119. Logistic: 13. Electrical: 12. Operation: 7. OM KT: 6. A&S: 4. Rotary: 3. Tank Farm: 2.

By Contractor

DEL: 459. ATL: 337. IIW: 234. AJC: 202. UE: 31. RE: 25. AKS: 15. SWIFT: 14. WMS: 10. Afzal: 9.

Monthly Trend

Jul 2025: 61. Aug 2025: 304. Sep 2025: 77. Oct 2025: 74. Nov 2025: 81. Dec 2025: 74. Jan 2026: 116. Feb 2026: 93. Mar 2026: 97. Apr 2026: 207. May 2026: 70. Jun 2026: 107. Jul 2026: 120. Aug 2026: 2.
Observations List 1483 records
No Date Type Department Description Assigned To Status Closed Date Actions
103 09 Aug 2025 Unsafe Act Stationary Welding Supervisor Changed The Grinder Disc Without Disconne … Closed 10 Aug 2025
102 08 Aug 2025 Unsafe Act Construction At tank#05, a worker was observed inside the tank during san … team Closed 10 Aug 2025
101 08 Aug 2025 Unsafe Condition Construction At tank#11, for the MS plate fit-up, wedge, U-clamps, and ji … Closed 09 Aug 2025
100 08 Aug 2025 Unsafe Act Construction At tank#11, one worker was working at height without clippin … Closed 10 Aug 2025
99 08 Aug 2025 Unsafe Condition Construction At road no#12, at sprinkle lines wall one cement block was … Closed 09 Aug 2025
98 08 Aug 2025 Unsafe Condition Construction At tank#05, three air compressors were being used for sand b … Closed 09 Aug 2025
97 08 Aug 2025 Unsafe Condition Stationary At tank#05, the distance between the three blasters during b … team Closed 10 Aug 2025
96 08 Aug 2025 Unsafe Act Stationary At tank#05, during the lifting operation, one rigger was hol … team Closed 09 Aug 2025
95 08 Aug 2025 Unsafe Condition Stationary Tank # 56 100kva diesel generator during operation radiator … Closed 09 Aug 2025
94 08 Aug 2025 Unsafe Condition Logistic At road #0, a PSO oil tanker, which arrived for fuel filling … team Closed 09 Aug 2025
93 08 Aug 2025 Unsafe Condition Stationary Electrical extension board # 13 damaged receptacle was repla … Closed 09 Aug 2025
92 08 Aug 2025 Unsafe Act Stationary During grinding works a fitter was observed having covered h … Closed 09 Aug 2025
91 08 Aug 2025 Unsafe Act Stationary 3 person of civil worker folding was erecting roof top of of … team Closed 10 Aug 2025
90 07 Aug 2025 Unsafe Act Stationary The safety shoes of 3 AJC workers were found damaged. Immedi … team Closed 09 Aug 2025
89 07 Aug 2025 Unsafe Act Stationary During crane operation rigger was not use tag line. Counseli … team Closed 09 Aug 2025
88 07 Aug 2025 Unsafe Condition Tank Farm A product line running from Tank 38 to Tank 01 had leakage f … team Closed 08 Aug 2025
87 07 Aug 2025 Unsafe Condition Construction At tank#05, main entrance door was blocked, informed to HSE … team Closed 08 Jul 2025
86 07 Aug 2025 Unsafe Act Construction At tank#05, during sandblasting activity, the required safe … team Closed 08 Jul 2025
85 07 Aug 2025 Unsafe Act Stationary At road no#16 ,a worker was using a mobile phone, inform to … team Closed 18 Aug 2025
84 05 Aug 2025 Unsafe Act Construction At tank #05, during mechanical work on shell no.2, a scaffol … Closed 06 Aug 2025