| 83 |
05 Aug 2025 |
Unsafe Act |
Construction |
At Tank #11, two fire extinguishers of ATL had not been insp … |
— |
Closed |
06 Aug 2025 |
|
| 82 |
05 Aug 2025 |
Unsafe Act |
Construction |
Tt tank #05, C-channel was observed being lifted with a rope … |
— |
Closed |
05 Aug 2025 |
|
| 81 |
05 Aug 2025 |
Unsafe Act |
Construction |
At Tank #11, a worker was hammering without using a tool tie … |
— |
Closed |
05 Aug 2025 |
|
| 80 |
05 Aug 2025 |
Unsafe Act |
Construction |
At Tank #05, two workers were wearing damaged coveralls. Inf … |
team |
Closed |
05 Aug 2025 |
|
| 79 |
04 Aug 2025 |
Unsafe Act |
Construction |
At Tank #05, a rigger was observed not wearing gloves during … |
— |
Closed |
05 Aug 2025 |
|
| 78 |
04 Aug 2025 |
Unsafe Act |
Construction |
At tank #05, ATL electrician was on leave, and in his absenc … |
— |
Closed |
05 Aug 2025 |
|
| 77 |
04 Aug 2025 |
Unsafe Act |
Construction |
At tank #05, During the vacuum test on Tank No. 05 Today, th … |
— |
Closed |
05 Aug 2025 |
|
| 76 |
04 Aug 2025 |
Unsafe Act |
Construction |
At tank #05, During the dismantling of scaffolding inside Ta … |
— |
Closed |
05 Aug 2025 |
|
| 75 |
04 Aug 2025 |
Unsafe Condition |
Construction |
At tank #05, Grinder No. 32 (5-inch) suddenly stopped workin … |
— |
Closed |
05 Aug 2025 |
|
| 74 |
04 Aug 2025 |
Unsafe Act |
Construction |
At Tank #05, workers were not wearing N-95 masks during powe … |
— |
Closed |
05 Aug 2025 |
|
| 73 |
04 Aug 2025 |
Unsafe Condition |
Construction |
At Tank #05, Hot work canopy contained grass and combustible … |
— |
Closed |
05 Aug 2025 |
|
| 72 |
04 Aug 2025 |
Unsafe Condition |
Construction |
At tank #11, the 60 kVA generator at Tank No. 11 was repeate … |
— |
Closed |
05 Aug 2025 |
|
| 71 |
04 Aug 2025 |
Unsafe Condition |
Construction |
At Tank #05, two fabrication teams were performing parallel … |
team |
Closed |
05 Aug 2025 |
|
| 70 |
04 Aug 2025 |
Unsafe Act |
Construction |
At Tank #05, a fitter was observed not wearing over-glasses … |
team |
Closed |
05 Aug 2025 |
|
| 69 |
01 Aug 2025 |
Unsafe Condition |
Stationary |
At storm water pit, the regulator of gas cylinders were foun … |
— |
Closed |
02 Aug 2025 |
|
| 68 |
01 Aug 2025 |
Unsafe Act |
Construction |
At tank #05, M/S ATL worker was observed wearing damaged saf … |
— |
Closed |
02 Aug 2025 |
|
| 67 |
01 Aug 2025 |
Unsafe Condition |
Stationary |
At storm water pit, the generator tire was observed burst. I … |
— |
Closed |
02 Aug 2025 |
|
| 66 |
01 Aug 2025 |
Unsafe Condition |
Stationary |
At storm water pit, the trolley of the gas cutting set was o … |
— |
Closed |
02 Aug 2025 |
|
| 65 |
01 Aug 2025 |
Unsafe Condition |
Civil |
At road #07, cracks were observed on the steps of the walkwa … |
— |
Closed |
02 Aug 2025 |
|
| 64 |
01 Aug 2025 |
Unsafe Act |
Construction |
At tank #05, M/S ATL worker observed working without safety … |
— |
Closed |
02 Aug 2025 |
|